- The DXFH heat recovery system is composed of two heat recovery systems. The first system is a static system that recovers energy at the first stage. The second system is a heat pump condensing exhaust heat recovery system. After the first system is recovered , Which greatly improves the energy efficiency ratio of energy recovery through the second system. This system can ensure the best efficiency regardless of winter or summer.
- Due to the two-stage heat recovery system, it can work effectively in the environmental range of -10℃-38℃.
- Using LCD controller, easy to operate, implement multiple function settings, and have multiple protection functions.
- The machine has a unique system and structure design, which makes it very convenient to use, install and maintain.
Integrated super-efficient heat pump type heat recovery group (horizontal)
面积:
m²
空间:
m³
Product description
Product parameter
Model | DXFH35 | DXFH60 | DXFH100 | DXFH150 | DXFH250 | DXFH320 | DXFH450 | |
Power supply(V-Ph-Hz) | 220-1-50 | 220-1-50 | 220-1-50 | 220-1-50 | 220-1-50 | 380-3-50 | 380-3-50 | |
Fresh air(m³/h) | 350 | 600 | 1000 | 1500 | 2500 | 3200 | 4500 | |
Rank(m³/h) | 350 | 600 | 1000 | 1500 | 2500 | 3200 | 4500 | |
Refrigeration capacity(kw) | 2150 | 3450 | 5840 | 8720 | 12830 | 18390 | 21440 | |
Cooling consumption capacity(kw) | 680 | 1120 | 1700 | 2600 | 3800 | 5900 | 6440 | |
Heating capacity(kw) | 3490 | 5790 | 9410 | 14390 | 21190 | 30260 | 36010 | |
Security configuration | High-voltage switch, compressor overheat protection, exhaust overheat protection, compressor overcurrent protection, fan motor overcurrent protection, etc., three-phase phase sequence protection | |||||||
Refrigerant | Types of | R22(410A) | ||||||
Way to control | Thermal expansion valve | |||||||
Compressor | Types of | Spiral | Spiral | Spiral | Spiral | Spiral | Spiral | Spiral |
Rated power(kw) | 0.42 | 0.68 | 1.15 | 1.72 | 2.68 | 3.65 | 3.65 | |
Condensing side | Exhaust fan motor rated power(kw) | 0.15 | 0.32 | 0.48 | 0.55 | 0.7 | 1.5 | 2.2 |
Residual pressure outside the machine(Pa) | 120 | 150 | 150 | 150 | 150 | 250 | 250 | |
Evaporation side | Rated power of blower motor(kw) | 0.15 | 0.32 | 0.48 | 0.55 | 0.7 | 1.5 | 2.2 |
External static pressure (standard)(Pa) | 120 | 150 | 150 | 150 | 150 | 250 | 250 | |
Drain pipe | DN25 | |||||||
noise(dB(A)) | 42 | 44 | 48 | 51 | 53 | 54 | 56 | |
Machine weight(Kg) | 122 | 125 | 185 | 228 | 267 | 281 | 329 | |
Dimensions (length x width x height)(mm) | 1300x1240x370 | 1300x1240x370 | 1640x1440x410 | 1640x1440x500 | 1940x1690x650 | 1940x1690x650 | 2240x1890x710 |